.png)
OVERVIEW
NO MORE BROWN WATER & STAINS
Iron and manganese in well water cause brown or black stains, a metallic taste and a bad smell. They also block pipes, irrigation drippers, filters and RO membranes.
Catalytic media such as Filox R turn the dissolved iron and manganese into particles and filter them out, all in one vessel. In many cases no extra chemicals are needed, depending on the oxygen already in the water. The filter is backwashed automatically.
TYPICAL USES
- Well water for drinking
- Pretreatment before RO
- Hotels, laundries and buildings
- Irrigation and drip systems
HOW IT WORKS
INSIDE A IRON REMOVAL FILTER
If needed, air or a small dose of oxidant is added first. The catalytic media then turns iron and manganese into particles, which are trapped in the bed and washed out by the automatic backwash.
STEP 1
Raw water
Tap, well, river or sea
STEP 1
Well water
With dissolved iron and manganese
STEP 2
Oxidation
Air or dosing, only if needed
STEP 1
Raw water
Tap, well, river or sea
STEP 3
Catalytic media
Turns iron and manganese into particles
STEP 1
Raw water
Tap, well, river or sea
STEP 4
Backwash
Particles are washed out automatically
STEP 1
Raw water
Tap, well, river or sea
STEP 5
Clear water
No stains, no metallic taste
KEY FEATURES
WHY CHOOSE OUR IRON & MANGANESE REMOVAL
No more stains
Clear water for sinks, laundry and equipment.
Automatic backwash
Timer-controlled, keeps the media working.
Catalytic media
Filox R removes iron, manganese and H₂S.
Little or no chemicals
Often works with the oxygen already in the water.
Protects RO and equipment
Stops iron fouling in membranes and pipes.
Automatic control
Runs by itself, with valves and controller.
SPECIFICATIONS
TECHNICAL DATA
Each system is sized for its water. Send us your water analysis with the iron and manganese levels to get the right model.
Capacity range
Up to 1,500 m³/day
Removes
Iron, manganese, hydrogen sulfide
Media
Catalytic oxidation media [e.g. Filox R]
Oxidation
[Air or chemical dosing, if needed]
Backwash
Automatic, timer-controlled
Vessel material
[FRP or epoxy-coated steel]
Outlet iron / manganese
[Below x mg/L]
APPLICATIONS
WHERE OUR RO SYSTEMS ARE USED